BRAD LELAND HOME INSPECTIONS
Prepared For:
Client
Name
Concerning:
Address
of Property
_____________ By:
Brad H. Leland Lic.#
5229
___________________________________________________________________________________________________
The inspection of the property listed
above must be performed in compliance with the rules of the Texas Real Estate
Commission (TREC). The inspection is of conditions that
are present and visible at the time of the inspection, and all of the equipment
is operated in normal modes. The inspector must indicate which items are in need
of repair or are not functioning and will report on all applicable items
required by TREC rules. This report is intended to provide you
with information concerning the condition of the property at the time of
Inspection. Please read the report carefully. If any item is unclear, you should
request the inspector to provide clarification. It is recommended that you obtain as
much history as is available concerning this property. This historical
information may include copies of any seller's disclosures, previous inspection
or engineering reports, reports performed for or by relocation companies,
municipal inspection departments, lenders, insurers, and appraisers. You should
attempt to determine whether repairs, renovation, remodeling, additions, or
other such activities have taken place at this property. Property conditions change with time
and use. Since this report is provided for the specific benefit of the client(s),
secondary readers of this information should hire a licensed inspector to
perform an inspection to meet their specific needs and to obtain current
information concerning this property.
ADDITIONAL
INFORMATION PROVIDED BY BRAD LELAND HOME INSPECTIONS Report: The inspection report provided by Brad Leland Home
Inspections will contain the good faith opinions of the inspector
concerning the observable need, if any, on the day of the inspection, for the
repair, replacement, or further evaluation by experts of the items inspected.
Unless, specifically stated, this report will not include and should not be read
to indicate opinions as to the environmental conditions, presence of toxic or
hazardous waste or substances, presence of termite or wood-destroying organisms,
or compliance with codes, ordinances, statutes or restrictions, or the
insurability, efficiency, quality, durability, future life, or future
performance of any item inspected. EXAMPLE When the inspector
inspects the roof of a structure he or she may determine that there are no
observable signs of water penetration (leaks) at the time of the inspection
and that the roof appears to be functioning as intended. Even if this opinion
is expressed, it is possible that the roof has a leak but that the ceilings or
walls have been repainted, concealing the evidence. Further, although the roof
may be functioning as intended at the time of the inspection, the roof still
may need to be replaced in the near future, depending on how long ago it was
installed.
Promulgated by the Texas Real Estate Commission (TREC) P.O. Box 12188, Austin, TX. 78711-2188, 1-800-250-8732 or (512) 459-6544 (http:www.trec.state.tx.us). rei 7a-0
Report
Identification _____(Property
Address}_________________________________________
l=Inspected
NI=Not Inspected
NP=Not Present
R=Not Functioning or In Need of Repair
I
NI
NP
R
Inspection
Item
I.
STRUCTURAL SYSTEMS
X
[
[
X
A. Foundation TYPE:
Concrete
Slab NOTE:
Please
read the supplement and be aware of the conditions surrounding your foundation,
an opinion on the condition of this foundation by our company is not a warranty
against future conditions. As not all portions of the foundation were
accessible, it is possible that there may be other undisclosed or hidden
defects. A professional (structural) engineer has other methods available
(survey equipment, excavation) that may increase their ability to accurately
determine the condition of the foundation.
There are many factors that can affect the performance of the foundation.
The condition of the foundation can rapidly change. COMMENT: There are signs of more than normal past movement in the structure such as, cracks in the exterior brick veneer on the west side of the home, cracks in the interior sheetrock in several areas of the home, and doors in the hallway that are not shutting properly. As discussed, these conditions indicate that the foundation may require a permanent remedy to stabilize the structure in some areas. The best course to follow for foundation settlement is to consult a professional (structural) engineer so that a course of corrective procedures can be evaluated. This can consist of a certification that the foundation is functioning as intended at this time, or alternately, a plan may be designed for underpinning. Although
the foundation for the separate garage appears to be performing properly at this
time, cracks were observed in several areas in the finished concrete surface. As discussed these cracks should be monitored in
the future for further activity, as some may be more than cosmetic surface
cracks. X
[
[
X
B. Grading and Drainage
NOTE:
The
foundation does not have positive drainage as there is rainwater collecting
on the west side of the home.
The drainage strategy of the yard as it relates to the foundation is important.
Expansive soils can be destructive to the foundation if the moisture content of
the perimeter varies. Improvement
should be made to the grading of the yard in this/these areas. The soil levels are high against the exterior grade
beam at the left rear corner of the home.
When soil levels are high against the face of the foundation it promotes
water penetration of the structure and insect infestation.
This item should be corrected so there is some exposure of the foundation
face. It is generally accepted that
in an ideal situation, a brick veneer house should have about 4-6 inches of
clearance. Wood siding houses should have more clearance. X
[
[
X
C. Roof Covering
TYPE:
Composition Shingle METHOD
OF INSPECTION: Ground level
and attic COMMENT: There
were trees impinging at the northeast corner of the roof.
Tree branches can damage a roof even in a gentle breeze whenever a tree is in
contact with the roof structure, we recommend trimming the tree or branches back
aggressively. As
discussed, the flashing at the plumbing vent stack near the chimney has lifted above the plane
of the roof line.
This condition is considered a conducive condition for water penetration and can
be uplifted in high winds. Sealing and securing the flashing is recommended. It was noted
that the gutter down spout at the southeast corner of the home is split at one of the
seams. It was also noted that the gutters were rusting in several locations
around the home. X
[
[
X
D. Roof Structure and Attic METHOD
OF INSPECTION: Crawled the attic area COMMENT: Evidence of water penetration was detected where the plumbing vent stack near the chimney goes through the roof. A moisture detector was used to determine that this is an active leak. Separations were detected between many of the rafters and the ridge boards in the attic area. In my opinion, these separations are an indication that the foundation has more than normal movement occurring. Some of the eve vent screens appeared to be blocked with insulation.
It is recommended that this condition be addressed whenever possible. Attic
ventilation is important, in cold weather the hot moist air will condense on the
roof structure members and in hot weather, the radiant heat will make the air
conditioning system work harder than necessary. Improving
this situation will decrease your energy costs as well. A
licensed roofing contractor should be consulted regarding the repair of the
above items. X
[
[
X
E.
Walls (Interior and Exterior) COMMENT:
Evidence of
insect infestation was observed to the right of the entry. It would be necessary
to remove the sheetrock in this area in order to properly inspect the inside of
the walls. Some
insects can cause damage to the structures they infest. A licensed pest control
company should be consulted so a corrective course of action can be evaluated. There were
cracks in the interior gypsum wall board in several areas throughout the home,
and cracks in the exterior brick on the west side of the home.
Cracks near the interior windows and doors are usually indications that
there is some degree of movement occurring in the structure.
The severity of the cracks can be an indication of the amount of movement
in a structure. These cracks should be repaired and monitored in the future for
further movement. It was noted
that some of the exterior siding and trim around the windows of the north side
of the home have been water damaged.
Water damaged materials are considered a conductive condition for further water
penetration and insect infestation. Whenever water damaged materials are noted
in this report, I recommend consulting a qualified contractor so a corrective
course of action can be evaluated. X
[
[
[
F. Ceilings and Floors
COMMENTS: Appear
to be functioning properly at this time. X
[
[
X
G. Doors
(Interior and Exterior)
COMMENTS: There
is no self-closing device on the door from the house leading to the garage. It is strongly recommended that one be installed
in order to protect the residence against garage originated fires. The sliding screen doors were not installed at the time of this inspection. Screens are mentioned in this part of the report as they are a specific item in the T.R.E.C. Guidelines. All sliding glass doors that have channels for screens should have them installed. It was noted that the
bottom of the front door is water damaged, and is not sealing properly when
shut. The right front bedroom
closet door did not latch properly and the master bedroom closet door sticks. All
doors should be present and in working order.
Doors that stick or do not latch properly can usually be adjusted.
In most cases, doors that stick or do not latch properly are an
indication of past differential settlement in a structure. X
[
[
X
H. Windows COMMENTS: Several of the window screens were missing. Screens are mentioned
in this part of the report as they are a specific item in the T.R.E.C.
Guidelines. Screens that are torn
enough to allow insect infestation should
be repaired or replaced. All
windows that have channels for screens should have them installed. The window springs on
two of the windows in the master bedroom are not operating properly. A window
spring is designed to keep a window open. Weak or defective window springs can
allow the windows to slam down unexpectedly. This condition can result in broken
glass panes or other related injuries. Defective window springs should be
replaced. There were broken glass
panes in one of the dining room windows.
Broken glass is considered a recognized safety hazard and limits the
energy efficiency of the glass. Effort
should be taken to exclude the use of defective windows until such time as they
can be repaired. X
[
[
X
I. Fireplace/Chimney COMMENTS:
There were gaps in the firebox area.
Cracks in the fire brick or gaps in the mortar can result in house fires. Most
small openings can be sealed using a temperature rated fireplace caulk. I
recommend consulting a chimney sweep service company so a corrective course of
action can be evaluated. It was also observed that the fireplace damper would not close easily at the
time of this inspection. X
[
[
[
J.
Porches, Decks and Carports (Attached) COMMENTS: It was noted that there is earth to wood contact at
the deck area in the back of the home. This
condition promotes water and insect penetration. I
recommend consulting a licensed pest control operator to determine if a need for
treatment exists. X
[
[
X
K.
Other COMMENTS: Separations and
cracks were observed in the brick planter of the front entry. As discussed this brick planter should be repaired or removed
completely. II.
ELECTRICAL SYSTEMS
X
[
[
X
A. Service Entrance
and Panels NOTE: The breaker box should be accessible at all times
and located outdoors if possible. In the event of a fire, immediately trip the
main breaker to expedite rescue/evacuation procedures. COMMENTS:
One of the
breakers in the service box had more than one wire connected to it. If a breaker has more than one wire, it must be
mentioned in this report. Multiple
wires are a recognized hazard for house wiring. Adding additional breakers, or
if there are not enough circuits for the structure, an extra sub box may be a
good alternative. A qualified
electrician should service the system. The power
lines were too close to the ground.
The proper clearance for the overhead wires is important. This condition can
present a shock hazard. If low lines are detected, a correction of the condition
may have to wait until the house has major electrical modifications. Use caution
around service wires as there are no safety devices to prevent death from
accidental electrocution. X
[
[
X
B. Branch Circuits – Connected Devices and Fixtures
NOTE:
The ground fault circuit
interrupt breaker is a safety device that can protect against electrical shock.
It can break the circuit in 1/60th of a second if a fault to the grounding is detected. These
breakers should be tested occasionally and replaced when they no longer protect
the circuit. COMMENTS:
Wires were improperly
spliced or terminated in the attic area over the garage.
Wire ends or splices should be in junction boxes that are properly
mounted. This condition is
considered an electrocution/fire hazard and should be serviced by a licensed
electrician. The
kitchen is not properly protected by G.F.C.I. (Ground Fault circuit interrupt)
breakers. This is required statement by the T.R.E.C.
(6/13/94) G.F.C.I. Breakers are required at all outlets within 6' of any water
source inside the house (kitchen sinks, bathrooms, wet bars, or utility room
sinks), all exterior outlets, and all outlets in the garage, except for one that
may be set aside for an extra refrigerator or freezer. It was also noted that there
is no power to several outlets in the garage area. A licensed electrician should be consulted so that a corrective course of action can be evaluated regarding the above items. III HEATING, VENTILATION, AND AIR CONDITIONING SYSTEMS X
[
[
X
A. Heating Equipment ENERGY
SOURCE: Gas NOTE: "The full evaluation of the integrity of a
heat exchanger requires dismantling of the furnace and is beyond the scope of
this visual inspection." (This is a specific T.R.E.C. Guideline
Limitation.) COMMENT:
The copper gas line does not meet T.R.E.C. Guidelines.
The gas line should be replaced with a flex type tubing that is lined on the
inside to prevent corrosion. The scent of the gas has an excess of hydrogen
sulfide which is corrosive to the copper line. It was noted that the flue pipe is not of the required double wall type for fire resistance and is also too close to the roof decking.. These flue pipes are required to have a minimum of 1” clearance from any combustible materials. X
[
[
X
B. Cooling Equipment TYPE
AND ENERGY SOURCE: Electric
with refrigerant gas NOTE:
Testing the differential
temperature of the supply (ambient) air and the return (vent) air is the best
test available (without releasing gasses into the environment) for diagnosing
the present condition of the air-conditioning equipment. The normal range is
between 14.0 f. and 21f. COMMENTS: The system did not operate within the allowable tolerances. The air coming out of the vents should be 14 to 21 degrees cooler than where it goes into the cold air return. It is recommended that a qualified contractor be consulted regarding this matter. The refrigerant line was not fully insulated to the coil box
unit. This condition causes the line to sweat and
slightly degrades the performance of the system and may also cause water damage
since it is located in the attic area. Applying new foam tubes and taping them
will remedy this condition. Water was detected in the safety pan under the coil box in
the attic area. This condition can cause severe damage if the
safety pan was to overfill. A
licensed HVAC technician should address this situation as soon as possible The safety
pan drain line is not visible from the exterior of the home, and appears to be
residing inside of the soffit area. In
the event of system failure, the water that is coming out of this drain line
should be as visible as possible, and should not be positioned in an area that
could cause damage to the structure. The exterior compressor
unit was not level. The
compressor should sit as level as possible, as well as have a 1foot clearance
between it and any other obstacles. Trimming shrubs that grow near the
compressor is a good idea. A qualified HVAC technician should be consulted regarding the repair of
the above items. X
[
[
X
C. Ducts and Vents COMMENTS: The
filters were dirty. Proper
filtering of the air is important. A defective filtering system can lead to
dirty evaporative coils and allergy problems.
It is a good idea to change or clean these filters every month or as
suggested by the manufacturer. It was noted that the air supply to the hall bathroom is inconstant
with the rest of the home. This is an indication that the system is not properly
balanced in this area.
III.
PLUMBING
SYSTEM
X
[
[
X
A. Water Supply System and Fixtures NOTE:
Be sure to caulk any
gaps that may appear between the hardware & tile of the fixtures or shower
enclosures. Most tile surfaces will have gaps in the grout that can also allow
for water penetration past the tile work. A leak in any one of these areas can
cause concealed structural damage that would not be obvious in a visual
inspection. COMMENTS:
The water pressure was
low at the hall bathroom tub/shower unit.
Water pressure is determined by running two faucets at the same time. There is
no guideline for flow rates. If the water pressure appears to be very low, it is
mentioned in this report. As there are several causes for low water pressure, a
licensed plumber should service the utility. There is a leak at the
cold water supply for the kitchen sink faucet.
Leaks can promote water penetration to the structure. Concealed damage is a
possibility. The faucet should be serviced and any damaged elements replaced or
repaired. The hall bathroom
tub/shower diverting valve did not operate properly.
This valve should completely restrict the flow of water from the bathtub
faucet and direct the pressure to the shower head.
Weak of defective diverting valves should be repaired or replaced when
they no longer function properly.
X
[
[
X
B.
Drains, Wastes, Vents COMMENTS: There
is a leak at the drain for the whirlpool bathtub unit in the master bathroom.
Leaks can promote water penetration to the structure. Concealed damage is a
possibility. The drain should be serviced and any damaged elements replaced or
repaired. The toilet in the master bathroom is loose at the floor. The toilets should be tight, a new wax ring seal may be necessary in order to prevent water leaks and possible damage to the surrounding structure and floors. X
[
[
X
C. Water Heating Equipment TYPE: Gas NOTE:
Water heaters have been
given special attention in the T.R.E.C. Guidelines. Although most water heaters
conformed to code when they were first installed, they may no longer meet
industry standards. For this reason, it is not unusual to have a few items
reported as “in need of repair” under this section. Temperature &
pressure relief valves that are more than three years old will not be operated
by the inspector as these valves are out of warranty and are in need of
replacement according to the manufacturer.
COMMENTS: The TPR valve needs an elbow pointing down at the exterior
termination. The
temperature and pressure relief valve should drain into a line that is plumbed
to the outside and may go horizontally or down, but cannot go back up. (This
keeps debris from going back to the valve) This line can be ¾ " C.P.V.C
Plastic (not reduced in size) and should terminate from 2 to 6 inches from the
ground. The water
heater was not elevated above the floor.
The water heater needs to be elevated 18" above the floor. The combustible
gases from vehicles, tools and even solvents are heavier than air. Proximity of
an ignition source poses a definite fire hazard. The T.R.E.C. Guidelines are
specific that all water heaters in the garage and adjoining rooms are to be
elevated. Corrosion
was observed at the water lines of the water heater. It is recommended that these fittings be replaced
whenever possible to prevent future leaks. A qualified plumber should be consulted regarding the repair of the above items. X
[
[
X
D. Hydro-Therapy Equipment COMMENTS:
The hydro-therapy
equipment does not appear to be protected by a G.F.C.I breaker. A ground fault circuit interrupt type of breaker
should be present as required by the T.R.E.C. The presence of these breakers can
save lives. It was noted that there is a switch or outlet within 5 feet of the whirlpool unit, this is also a recognized safety hazard. V.
APPLIANCES
X
[
[
X
A. Dishwasher COMMENTS: The soap dispenser dish of the dishwasher did not
open when the unit was cycled nor did the sprayer arm function properly. It appears that the bottom basket was not intended
for use with this unit and is interfering with the normal operation of the unit.
The normal cycle has two wash cycles. When the soap dispenser does not operate,
the second washing does not take place. The unit should be serviced by a
qualified appliance technician. X
[
[
X
B. Food Waste Disposer COMMENTS: The unit was
loud, and vibrated excessively when operated. Although the unit is operating as
intended at this time, this may be an indication that it is going to need
service in the near future. X
[
[
X
C. Range Hood COMMENTS:
The range
top has a re-circulating vent-a-hood.
After the air is filtered, and then it is re-deposited in the kitchen.
Most vent-hood appliances, especially ones that use gas, will usually
have a flue which is terminated outside of the house to remove combustion
products, moisture, grease, and heat. The installation of a flue will also lower
your electric bill during the hot months. The
interior surface of the vent duct in the attic area was not of a rigid slick
kind.
As discussed, grease can accumulate in the flexible duct vents and become a fire
hazard. X
[
[
X
D. Ranges/Ovens/Cooktops COMMENTS:
The range is not properly secured to the
surrounding cabinet or wall. Children
can tip the oven over if the door is used as a stepping stool. All ovens are now
required to be secured in some fashion. An anti-tip device should be installed. The left rear burner
element did not work. Burners and
heating elements are operated on low an high settings. If the burners or heating
elements do not operate on one of these settings, it must be mentioned in this
report. The oven or cook top knobs are illegible. New control knobs can be purchased at most home improvement stores. X
[
[
[
E. Microwave Cooking Equipment COMMENTS: Appears to be functioning properly at this time. [
[
X
[
F. Trash Compactor COMMENTS: Not present X
[
[
X
G. Bathroom Exhaust Fans and/or
Heaters COMMENTS: The bathroom exhaust fans vent ducts terminate
inside the attic area. This
condition adds moisture in the attic. The exhaust vent should terminate near one
of the roof vents. Additional duct material can be purchased at most home
improvement stores. [
[
X
[
H. Whole House Vacuum Systems COMMENTS: Not present X
[
[
X
I. Garage Door Operators COMMENTS: The safety reversing
mechanism is out of adjustment. When
the inspector tests the safety reversing mechanism of the garage overhead door,
the motor should reverse itself. (5
lbs of pressure over a 2 second period should be sufficient to reverse most
doors) Failure to reverse is considered a recognized hazard by the Texas Real
Estate Commission (T.R.E.C.) These motors can usually be adjusted. X
[
[
[
J. Door Bell and Chimes COMMENTS: Appears to be functioning properly at this time. X
[
[
X
K. Dryer Vents COMMENTS:
The
dryer vent exceeds the maximum distance recommended by the Texas
Real Estate Commission. The
distance should not be more than 25', subtracting 5' for every 90 degree turn,
and 2 ½' ' for every 45 degree turn. [
[
X
[
L. Other Built-In Appliances COMMENTS: Not
present |